Which of the following should be taken into account when selecting the location and position of a rooftop package unit?
A. Possible snow accumulation
B. Condenser air circulation
C. Serviceability
D. All of the above
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Which of the following is true regarding the refrigerantpiping on a rooftop package unit?A. The discharge and liquid lines must be field installed.B. The suction and liquid lines must be field installed.C. The discharge and suction lines must be field installed.D. No refrigerant lines are field installed.
Which of the following components is NOT a type of ventilation system?
Select one:
a. Airconditioning Units
b. Venting Skylight
c. Boilers
d. Exhaust Fans
Which list states the correct order of components for the absorption refrigeration? A) Evaporator, then absorber, then concentrator, then condenser. B) Absorber, then condenser, then evaporator, then concentrator. C) Condenser, then absorber, then concentrator, then evaporator.
Chapter 50 Solutions
Refrigeration and Air Conditioning Technology (MindTap Course List)
Ch. 50 - Which of the following is true regarding the...Ch. 50 - Which process would best represent the opposite of...Ch. 50 - Mixed air is best described as the combination of...Ch. 50 - Which of the following should be taken into...Ch. 50 - A bonded roof is one that has A. reinforced steel...Ch. 50 - Properly installed roof curbs will reduce the...Ch. 50 - When rigging a unit to the roof, what minimum...Ch. 50 - What is the acceptable method for communicating...Ch. 50 - Prob. 9RQCh. 50 - Prob. 10RQ
Ch. 50 - The most efficient way to establish the best...Ch. 50 - Free-cooling can be accomplished if the
A....Ch. 50 - Prob. 13RQCh. 50 - Prob. 14RQCh. 50 - Explain why the outside air damper is typically...Ch. 50 - Briefly explain the purpose of ASHRAE Standard 62.Ch. 50 - Explain the concept of demand control ventilation.Ch. 50 - Explain how carbon dioxide levels can be used to...Ch. 50 - Describe the blowers used on VAV systems.Ch. 50 - A cooling-only VAV box has all of the following...Ch. 50 - Which of the following is true regarding a reheat...Ch. 50 - Variable refrigerant flow systems sense the...Ch. 50 - The acronym PID stands for ______, _____, and...Ch. 50 - Explain the main benefit of a heat-recovery VRF...Ch. 50 - The pump on a dry cooler can direct water to...Ch. 50 - During low ambient conditions, the space cooling...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Which device can be used to recover waste heat from flue gas? a. flue gas recoverer b. boiler saver c. energy saver d. feedwater economizerarrow_forwardMultiple-zone systems often use a(n) __________or a(n)___________to alleviate the problem of excess air when only some zones are calling for conditioning.arrow_forward(b) Bathroom sinks and some other fixtures include an overflow opening in the basin. This opening is located on the wall and near the top of the basin. The overflow opening serves two important functions: If the water tap is left on while the drain stopper is closed, the opening will channel water down into the drain opening rather than letting is spill out of the sink onto the floor. The overflow allows the sink to drain faster by introducing air into the system. A sink with a dimension given in Figure Q2(b), has water flows into it at a rate of 8 L/min. If the drain stopper is closed and water level in the sink remains constant, determine the average velocity of water flows through the 3.0 cm diameter overflow hole. Front 3 cm diameter overflow holes Q-8 L/min 15 3/4| 40 cm 15 cm Side (a) Figure Q2: (a) Picture of the sink; (b) Sink dimension (Ь)arrow_forward
- What is the total length of this furnace and air-conditioning system?arrow_forwardExplain basic sauna and steam room installation.arrow_forwardWhich of the following would not increase the rate of heat transferred from a heater pipe? A. Insulating with materials whose thickness is below that of critical thickness for insulation. B. Blowing air over it C. Providing fins D. Placing the heater pipe within another whose thermal conductivity is smaller in number and 2 inches thickarrow_forward
- Describe the function of a multipoise or multipositional furnace.arrow_forwardWhich process would best represent the opposite ofexhausting air from a system?A. CoolingB. VentilatingC. HeatingD. Filteringarrow_forwardQuestion 5 In the Benson boiler given below, what is A? Steam to prms mover Transit section Water Steam Fadiert peralel Feed ube section pump evaporator convection super heater economizer O pumparrow_forward
- 10. A crankcase heater is used to warm a compressor to prevent the condensing of the crankcase. A. moisture inside B. moisture outside C. oil inside -D. refrigerant insidearrow_forward1. An air-source heat pump is a heat-pump system that uses air: a. as the system refrigerant. b. as the heat source when operating in the cooling mode. c. as the heat sink when operating in the heating mode. d. as the heat source when operating in the heating mode. 2. According to the Department of Energy, duct leakage can result in a energy loss? a. 10% b. 20% c. 30% d. 40% 3. As the outside ambient temperature drops, the efficiency of a heat-pump system operating in the mode will: a. heating, drop b. heating, rise c. cooling, rise d. Both a and c are correct.arrow_forwardc) Explain the layout and the basic operation of a centralized air conditioning system(or chiller system).arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage LearningAutomotive Technology: A Systems Approach (MindTa...Mechanical EngineeringISBN:9781133612315Author:Jack Erjavec, Rob ThompsonPublisher:Cengage LearningWelding: Principles and Applications (MindTap Cou...Mechanical EngineeringISBN:9781305494695Author:Larry JeffusPublisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Automotive Technology: A Systems Approach (MindTa...
Mechanical Engineering
ISBN:9781133612315
Author:Jack Erjavec, Rob Thompson
Publisher:Cengage Learning
Welding: Principles and Applications (MindTap Cou...
Mechanical Engineering
ISBN:9781305494695
Author:Larry Jeffus
Publisher:Cengage Learning
Heat Transfer [Conduction, Convection, and Radiation]; Author: Mike Sammartano;https://www.youtube.com/watch?v=kNZi12OV9Xc;License: Standard youtube license