Electric Motors and Control Systems
2nd Edition
ISBN: 9780073373812
Author: Frank D. Petruzella
Publisher: McGraw-Hill Education
expand_more
expand_more
format_list_bulleted
Question
Chapter 4.2, Problem 10RQ
To determine
The comparison of the function of a float switch with that of a flow switch.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Select the proper choice(s) for each of the following statements:
1) To control single-acting cylinder we just need:
double-acting cylinder we should use
A2/2-way, 5/2-way,
(C) 3/3-way, 3/4-way,
2) In
DCV.
(B) 3/2-way, 4/2-way,
(D) 4/3-way, 3/2-way.
mid poistion of DCV, we can move cylinder piston rod freely without
resistance by hand.
(A) working ports are exhausted,
(C) working ports are pressurized,
3) In pneumatics we use
A Compressor
(B) Pump,
DCV, while to control the
4) Quick exhaust valve is used to
(A) increase the cylinder return speed.
(C) meter-out the cylinder speed
(B) all ports are closed.
no one of these options.
to obtain high pressure air.
(C) Turbine,
(D) pressure relief valve.
(B) meter-in the cylinder speed,
(D) increase the cylinder extending speed.
6) Meter-in of cylinder movement is used to control the
Afluid that enters the hydraulic cylinder,
(B) fluid that exits the hydraulic cylinder,
(C) fluid that enters the DCV
(D) fluid that exits the DCV.
5) One of the…
Explain the Interruption Cycle with neat sketch.
Name
Section 5-2: Line Diagrams-Signals,
Decisions, and Actions
In the following application, a temperature switch controls a heating contactor and a flow switch is used to
ensure there is enough air flow. If there is not enough air flow, an alarm is sounded. Complete the required
information.
1. List all the signal devices in the circuit.
2. List all the action devices in the circuit.
3. List the decision part of the circuit that automatically sounds the alarm if there is a problem.
4. When the heating element is on during normal operation, is the flow switch open or closed?
CIRCULATING
2
L1
FAN
TEMPERATURE
SWITCH
TR
HEATING
ELEMENTS
FLOW
SWITCH
-HOT AIR
PADDLE
AIR FILTER
NORMALLY CLOSED
FLOW SWITCH
65
ALARM
(SOUNDS IF NO FLOW FOR
15 SECONDS OR MORE)
Date
HEATING
CONTACTOR
TR
ON-DELAY
TIMER
SUPPLY AIR
COLD AIR
(3) TIME SET= 15 SEC
© 2014 American Technical Publishers, Inc.
All rights reserved
Chapter 4 Solutions
Electric Motors and Control Systems
Ch. 4.1 - Prob. 1RQCh. 4.1 - Prob. 2RQCh. 4.1 - What do the terms normally open and normally...Ch. 4.1 - The types of enclosures used to house motor...Ch. 4.1 - Prob. 5RQCh. 4.1 - Compare the operation of momentary and maintained...Ch. 4.1 - What is the OSHA requirement for resetting...Ch. 4.1 - Prob. 8RQCh. 4.1 - Explain how a push-to-test pilot light operates.Ch. 4.1 - Compare the way in which pushbutton and selector...
Ch. 4.1 - Prob. 11RQCh. 4.2 - Define the term mechanically operated switch.Ch. 4.2 - In what way are limit switches normally actuated?Ch. 4.2 - A control application calls for an NC held open...Ch. 4.2 - List four common types of limit switch operator...Ch. 4.2 - Prob. 5RQCh. 4.2 - Prob. 6RQCh. 4.2 - For what types of machine control applications are...Ch. 4.2 - How does a fluid capillary tube temperature switch...Ch. 4.2 - Prob. 9RQCh. 4.2 - Prob. 10RQCh. 4.3 - In general, how do sensor pilot devices operate?Ch. 4.3 - What is the main feature of a proximity sensor?Ch. 4.3 - List the main component of an inductive proximity...Ch. 4.3 - Explain the term hysteresis as it applies to a...Ch. 4.3 - How is a two-wire sensor connected relative to the...Ch. 4.3 - In what way is the sensing field of a capacitive...Ch. 4.3 - For what type of target would a capacitive...Ch. 4.3 - Prob. 8RQCh. 4.3 - Name the three most common scan techniques for...Ch. 4.3 - What are the advantages of fiber optic sensing...Ch. 4.3 - Outline the principle of operation of a Hall...Ch. 4.3 - Outline the principle of operation of an...Ch. 4.3 - List the four basic types of temperature sensors...Ch. 4.3 - Compare the way in which a tachometer and magnetic...Ch. 4.3 - Outline the principle of operation of an optical...Ch. 4.3 - What approach is usually taken to measurement of...Ch. 4.3 - Prob. 17RQCh. 4.4 - Define the term actuator as it applies to an...Ch. 4.4 - In what ways are electromagnetic relays employed...Ch. 4.4 - Prob. 3RQCh. 4.4 - Prob. 4RQCh. 4.4 - Prob. 5RQCh. 4.4 - Prob. 6RQCh. 4.4 - Prob. 7RQCh. 4.4 - Prob. 8RQCh. 4.4 - Prob. 9RQCh. 4.4 - What is the basic difference between an open-loop...Ch. 4.4 - Prob. 11RQCh. 4.4 - Prob. 12RQCh. 4.4 - In what way docs a double-break contact differ...Ch. 4.4 - Prob. 14RQCh. 4.4 - Prob. 1TCh. 4.4 - Prob. 2TCh. 4.4 - Prob. 4TCh. 4.4 - Prob. 5TCh. 4.4 - A through-beam photoelectric sensor appears to be...Ch. 4.4 - Prob. 1DTCh. 4.4 - Prob. 2DTCh. 4.4 - Prob. 3DTCh. 4.4 - What does the range adjustment on a float switch...Ch. 4.4 - A stepper motor cannot be bench-checked directly...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- The colors of the wires of the thermocouple type K are: Select one: a. Green and white. b. Black and white. c. Green and black. d. Brown and white.arrow_forwardDefine relayarrow_forwardRefer to Figure 211 to answer the following questions. Referring to switch (RS SW 123), in what position must the switch be set to make connection between terminals 3 and 4?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage LearningUnderstanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage LearningAutomotive Technology: A Systems Approach (MindTa...Mechanical EngineeringISBN:9781133612315Author:Jack Erjavec, Rob ThompsonPublisher:Cengage Learning
- Electrical Transformers and Rotating MachinesMechanical EngineeringISBN:9781305494817Author:Stephen L. HermanPublisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning
Automotive Technology: A Systems Approach (MindTa...
Mechanical Engineering
ISBN:9781133612315
Author:Jack Erjavec, Rob Thompson
Publisher:Cengage Learning
Electrical Transformers and Rotating Machines
Mechanical Engineering
ISBN:9781305494817
Author:Stephen L. Herman
Publisher:Cengage Learning
Mod-01 Lec-16 Basics of Instrumentation; Author: nptelhrd;https://www.youtube.com/watch?v=qbKnW42ZM5c;License: Standard YouTube License, CC-BY