Fundamentals of Electric Circuits
6th Edition
ISBN: 9780078028229
Author: Charles K Alexander, Matthew Sadiku
Publisher: McGraw-Hill Education
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
Chapter 12.2, Problem 1PP
Given that
Answer:
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
termining the impedance and current of the system, the voltage across the resistor, and the voltage across the inductor.
Could you please forward the response as a print of a handwritten answer?
I got these two answers earlier. Which of them would be correct
Impedance Z= (1000 + j 90.836) ohm
Current I= 0.219∠-5.19° A
Voltage across resistor VR = 219.097∠-5.19° V
Voltage across inductor VL = 165.195∠84.81° V
Impedance will be Z= 1004.052 ∠ 5.12°
Current will be i = 0.221 ∠ -5.19° A.
Volatge across resistor will be VR = 211.9∠ -5.19° V
Volatge across inductor will be VL = 165.12 ∠ 84.81°V
[Q3] Analyze the following electrical circuit with mesh analysis by finding the
currents using Gauss-elimination method
10 Q
15 Q
25 0
20Q
35Q
- 1000 V
1000V
2000 V
2000 V
30 2
40 Q
Change Delta to star transformation equation to find Ra , Rb, and Rc as shown in
the figure.
R,
Re
2. 2
Chapter 12 Solutions
Fundamentals of Electric Circuits
Ch. 12.2 - Given that Vbn=22030V, find Van and Vcn, assuming...Ch. 12.3 - A Y-connected balanced three-phase generator with...Ch. 12.4 - One line voltage of a balanced Y-connected source...Ch. 12.5 - A positive-sequence, balanced -connected source...Ch. 12.6 - In a balanced -Y circuit, Vab=44015 and ZY = (12 +...Ch. 12.7 - For the Y-Y circuit in Practice Prob. 12.2,...Ch. 12.7 - Calculate the line current required for a 30-kW...Ch. 12.7 - Assume that the two balanced loads in Fig....Ch. 12.8 - The unbalanced -load of Fig. 12.24 is supplied by...Ch. 12.8 - Find the line currents in the unbalanced...
Ch. 12.9 - Prob. 11PPCh. 12.9 - For the unbalanced circuit in Fig. 12.32, use...Ch. 12.10 - Repeat Example 12.13 for the network in Fig. 12.24...Ch. 12.10 - Let the line voltage VL = 208 V and the wattmeter...Ch. 12.10 - If the load in Fig. 12.35 is delta-connected with...Ch. 12 - What is the phase sequence of a three-phase motor...Ch. 12 - If in an acb phase sequence, , then Vcn is:Ch. 12 - Which of these is not a required condition for a...Ch. 12 - Prob. 4RQCh. 12 - Prob. 5RQCh. 12 - In a Y-Y system, a line voltage of 220 V produces...Ch. 12 - In a - system, a phase voltage of 100 V produces a...Ch. 12 - When a Y-connected load is supplied by voltages in...Ch. 12 - Prob. 9RQCh. 12 - Prob. 10RQCh. 12 - If Vab = 400 V in a balanced Y-connected...Ch. 12 - What is the phase sequence of a balanced...Ch. 12 - Given a balanced Y-connected three-phase generator...Ch. 12 - A three-phase system with abc sequence and VL =...Ch. 12 - For a Y-connected load, the time-domain...Ch. 12 - Using Fig. 12.41, design a problem to help other...Ch. 12 - Obtain the line currents in the three-phase...Ch. 12 - In a balanced three-phase Y-Y system, the source...Ch. 12 - A balanced Y-Y four-wire system has phase voltages...Ch. 12 - For the circuit in Fig. 12.43, determine the...Ch. 12 - In the Y- system shown in Fig. 12.44, the source...Ch. 12 - Using Fig. 12.45, design a problem to help other...Ch. 12 - In the balanced three-phase Y- system in Fig....Ch. 12 - Obtain the line currents in the three-phase...Ch. 12 - The circuit in Fig. 12.48 is excited by a balanced...Ch. 12 - A balanced delta-connected load has a phase...Ch. 12 - A positive sequence wye-connected source where ,...Ch. 12 - If Van = 22060 V in the network of Fig. 12.49,...Ch. 12 - For the - circuit of Fig. 12.50, calculate the...Ch. 12 - Prob. 20PCh. 12 - Three 440-V generators form a delta-connected...Ch. 12 - Find the line currents IaA, IbB, and IcC in the...Ch. 12 - A balanced delta connected source is connected to...Ch. 12 - A balanced delta-connected source has phase...Ch. 12 - In the circuit of Fig. 12.54, if , , , find the...Ch. 12 - Using Fig. 12.55, design a problem to help other...Ch. 12 - A -connected source supplies power to a...Ch. 12 - The line-to-line voltages in a Y-load have a...Ch. 12 - A balanced three-phase Y- system has V rms and Z =...Ch. 12 - In Fig. 12.56, the rms value of the line voltage...Ch. 12 - A balanced delta-connected load is supplied by a...Ch. 12 - Design a problem to help other students better...Ch. 12 - A three-phase source delivers 4.8 kVA to a...Ch. 12 - A balanced wye-connected load with a phase...Ch. 12 - Three equal impedances, 60 + j30 each, are...Ch. 12 - A 4200-V, three-phase transmission line has an...Ch. 12 - The total power measured in a three-phase system...Ch. 12 - Given the circuit in Fig. 12.57 below, find the...Ch. 12 - Find the real power absorbed by the load in Fig....Ch. 12 - For the three-phase circuit in Fig. 12.59, find...Ch. 12 - A balanced delta-connected load draws 5 kW at a...Ch. 12 - A balanced three-phase generator delivers 7.2 kW...Ch. 12 - Refer to Fig. 12.48. Obtain the complex power...Ch. 12 - A three-phase line has an impedance of 1 + j3 per...Ch. 12 - A balanced wye-connected load is connected to the...Ch. 12 - A three-phase load consists of three 100-...Ch. 12 - The following three parallel-connected three-phase...Ch. 12 - A balanced, positive-sequence wye-connected source...Ch. 12 - Each phase load consists of a 20- resistor and a...Ch. 12 - A balanced three-phase source with VL = 240 V rms...Ch. 12 - Consider the wye-delta system shown in Fig. 12.60....Ch. 12 - A four-wire wye-wye circuit has...Ch. 12 - Using Fig. 12.61, design a problem that will help...Ch. 12 - A balanced three-phase Y-source with VP = 880 V...Ch. 12 - A three-phase supply, with the line-to-line...Ch. 12 - Using Fig. 12.63, design a problem to help other...Ch. 12 - Determine the line currents for the three-phase...Ch. 12 - Solve Prob. 12.10 using PSpice or MultiSim. For...Ch. 12 - The source in Fig. 12.65 is balanced and exhibits...Ch. 12 - Use PSpice or MultiSim to determine Io in the...Ch. 12 - Given the circuit in Fig. 12.67, use PSpice or...Ch. 12 - Using Fig. 12.68, design a problem to help other...Ch. 12 - Use PSpice or MultiSim to find currents IaA and...Ch. 12 - For the circuit in Fig. 12.58, use PSpice or...Ch. 12 - A balanced three-phase circuit is shown in Fig....Ch. 12 - A three-phase, four-wire system operating with a...Ch. 12 - As shown in Fig. 12.72, a three-phase four-wire...Ch. 12 - Meter readings for a three-phase wye-connected...Ch. 12 - A certain store contains three balanced...Ch. 12 - The two-wattmeter method gives P1=1200W and...Ch. 12 - In Fig. 12.73, two wattmeters are properly...Ch. 12 - If wattmeters W1 and W2 are properly connected...Ch. 12 - For the circuit displayed in Fig. 12.74, find the...Ch. 12 - Predict the wattmeter readings for the circuit in...Ch. 12 - Prob. 75PCh. 12 - Show that the I2R losses will be higher for a...Ch. 12 - A three-phase generator supplied 10 kVA at a power...Ch. 12 - Prob. 78CPCh. 12 - A balanced three-phase generator has an abc phase...Ch. 12 - A balanced three-phase source furnishes power to...Ch. 12 - A professional center is supplied by a balanced...Ch. 12 - A balanced three-phase system has a distribution...Ch. 12 - A commercially available three-phase inductive...Ch. 12 - Figure 12.76 displays a three-phase...Ch. 12 - Design a three-phase heater with suitable...Ch. 12 - For the single-phase three-wire system in Fig....Ch. 12 - Consider the single-phase three-wire system shown...
Additional Engineering Textbook Solutions
Find more solutions based on key concepts
Analog Voltmeter Design Figure P2-98(a) shows a voltmeter circuit consisting of a D'Arsonval meter, two series ...
ANALYSIS+DESIGN OF LINEAR CIRCUITS(LL)
Does the severity of an electric shock increase ordecrease with eh of the following changes? a. A decrease in t...
Electric Motors and Control Systems
When travelers from the USA and Canada visit Europe, they encounter a different power distribution system. Wall...
Electric machinery fundamentals
How many coulombs do 93.8 1016 electrons represent?
Principles Of Electric Circuits
Identify the type of input and output configuration for each diff-amp in Figure 18-35.
Electronics Fundamentals: Circuits, Devices & Applications
Find I0 and I1 in the circuit in Fig.P2.12.
Basic Engineering Circuit Analysis
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Quèstion 17 Giving the following tank circuit, if L= 50 mH, R=102 and C=5µF. The approximate value of w, is L. C 1989.97 None of the answers 314.7 1150.36arrow_forwardGiven the complex numbers A1=630 and A2=4+j5, (a) convert A1 to rectangular form: (b) convert A2 to polar and exponential form: (c) calculate A3=(A1+A2), giving your answer in polar form: (d) calculate A4=A1A2, giving your answer in rectangular form: (e) calculate A5=A1/(A2*) giving your answer in exponential form.arrow_forward2Ω j5 N i 24315° (1 -j3 n= Y2 Y Find the admittance Y, and impedance Z2 looking into the circuit from the dashed line and the current i. Answer format = X.XX rounded to 2 decimal places, add O's as needed. Y1= + j %3D Y2 +j Sarrow_forward
- 7. Indicate which circuit would best match curves below, also indicate where the curve is C, L, R. Sketch the missing curve Zr A C ww 412) B 1 ww ell www E F 2,(0)arrow_forwardFor the circuit shown, calculate the magnitude of line current at line Aa. ΤΑ EAB = 208 V 0° ECA = 208 V 120° B EBC = 208 V Z-120° 5.5 A 21.25 A 29.08 A O 32.79 A roo W₁ W₂ moo ell ell IAa Bb Icc R3 Xc Ica 12 02 R₂ www 15 Q2 a 1292 ab R₁ 10 Q2 XL voo 20 Ω barrow_forwardFor the Single Line Diagram shown below, draw the reactance diagram and specify all reactance in . u.. Take Sp = 100 MVA, V, 33 kV M.) 40 MVA, x- 0.20 pu T1 T 30 kV 60 Q 38 38 100 MVA, 110MVA 110 MVA 110/33 kV = 0.08 pu 33 kV M 20 MVA. x= 0.20 pu X = 0.15 pu 33/110 kV X7, 0.08 pu 30 kVarrow_forward
- 011 (part 1 of 2) Consider the circuit 2. Vab 3 μF 2 μF क 5 μF 140 V 2 4. V-18 V 5. V-4 V 6. V-3 V 7. Vab- 2 V 8. V-9 V mecants (dm56498) – Homey What is the equivalent capacitance for this network? Answer in units of F. 012 (part 2 of 213 What is the charge stored in the 5 µF lower- right capacitor? Answer in units of µC.arrow_forward12 25 2 30 2 10 V + 12 50 2 55 2 Do the Gaussian elimination about this circuit and explain every single way of counting.arrow_forwardChange Delta to star transformation equation to find Ra , Rb , and Rc as shown in the figure. R, wwwA Rz 2. 2 wwwwarrow_forward
- /attempt.php?attempt-2276600 and 1120 b My Questions | bart... Translate Volvo Penta TAMD6... Sign in to your Micr... MATLAB Time left 0:43 For the circuit in Figure 2. What is the total impedance ZT in Polar form? R-10 X₁-20 ww E- 100V Xc= 155 430 Figure 2 OA B C D a. 11.180 angle 26.6deg a. 50 angle 10deg a 11.180 angle 63.43deg a 100 angle 5deg LGarrow_forward1. Plot the external characteristic curve for separately excited generator and find internal characteristic. RL(Q) V(V) I(A) 140 48 70 24 35 48//24 140//70//35 48//24//12 12 42 41.5 40.3 40.7 39.5 40.1 38.3 39.2 39.6 37 0.288 0.797 0.553 1.58 1.126 3.145 2.34 1.928 5.21arrow_forwardTransmission Power Lines Tutorials Tutorial n° 0: Construction of transmission power lines A Young Electrical Engineer proposes to build an electrical network with a starting voltage of 110 kV to supply a city with a power of 15 MW. He finds that his power line changes direction 8 times in its journey. The distance between the first support and the 1st change of direction is 3.5 km. Between the 2nd and the 3rd change of direction the distance is 5 km, while between the 6th and the 7th it is 4 km. The distances between the other changes of direction are 3 km. At the 4th change of direction, the line finds a branch to supply a 1.5 MVA load at station B located 6 km away. The distance between the last support and the last change of direction is 3.5 km. This line crosses a busy road three times. The distance between two supports is 250 m and the distance between two consecutive electrical crossing supports is 150m. The definition and the diagram of the layout, canton, range, arrow of the…arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
How do Electric Transmission Lines Work?; Author: Practical Engineering;https://www.youtube.com/watch?v=qjY31x0m3d8;License: Standard Youtube License