Q5. Assume that the following permanent outage data has been given for the system shown below: System Component Outage Rate Average (outages/yr) Repair Time(h) 138KV 69kV 138KV breakers 138KV Line 138/69Kv transformer 69Kv breakers 69Kv bus 0.0058 66 0.627 10 0.0119 0.0045 0.011 360 44 Assuming that 132Kv bus is 100% reliable and determine the following: a. Total failure rate for one parallel line. b. Total mean time to repair for one parallel iine. c. Total failure rate of the system. d. Total mean time to repair of the system.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question
Q5. Assume that the following permanent outage data has been given for the system shown below:
System
Component
Outage Rate Average
138kV
(outages/yr) Repair
69kV
Time(h)
66
138Kv breakers
138KV Line
138/69KV transformer
69KV breakers
69KV bus
0.0058
to
0.627
0.0119
0.0045
10
360
44
0.011
Assuming that 132Kv bus is 100% reliable and determine the following:
a. Total failure rate for one parallel line.
b. Total mean time to repair for one parallei iine.
c. Total failure rate of the system.
d. Total mean time to repair of the system.
Transcribed Image Text:Q5. Assume that the following permanent outage data has been given for the system shown below: System Component Outage Rate Average 138kV (outages/yr) Repair 69kV Time(h) 66 138Kv breakers 138KV Line 138/69KV transformer 69KV breakers 69KV bus 0.0058 to 0.627 0.0119 0.0045 10 360 44 0.011 Assuming that 132Kv bus is 100% reliable and determine the following: a. Total failure rate for one parallel line. b. Total mean time to repair for one parallei iine. c. Total failure rate of the system. d. Total mean time to repair of the system.
Expert Solution
steps

Step by step

Solved in 5 steps

Blurred answer
Knowledge Booster
Transmission line parameter
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,