Q3: Tikrit University has been implemented a project of an electrical portable station. This project includes installing two towers cach of them has a hight of 39 m to cary the overhead transmission line from outside to inside the University. And the distance between the towers is 300 m. But, the transmission line flow-through a ground has a gradient (slope) of 1/15. After calculating the sag, find the distance (clearance) between the orginal point and the ground. The tensile strength in the wire is 2500 N/cm2. The weight of one meter of the conductor is 9 N. The cross-section area of the conductor is 4 cm2.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter5: Transmission Lines: Steady-state Operation
Section: Chapter Questions
Problem 5.52P
icon
Related questions
Question
Q3:
Tikrit University has been implemented a project of an electrical portable station. This project
includes installing two towers cach of them has a hight of 39 m to cary the overhead transmission
line from outside to inside the University. And the distance between the towers is 300 m. But, the
transmission line flow-through a ground has a gradient (slope) of 1/15. After calculating the sag,
find the distance (clearance) between the orginal point and the ground.
The tensile strength in the wire is 2500 N/em2.
The weight of one meter of the conductor is 9 N.
The cross-section area of the conductor is 4 cm2.
(15 dearees)
Transcribed Image Text:Q3: Tikrit University has been implemented a project of an electrical portable station. This project includes installing two towers cach of them has a hight of 39 m to cary the overhead transmission line from outside to inside the University. And the distance between the towers is 300 m. But, the transmission line flow-through a ground has a gradient (slope) of 1/15. After calculating the sag, find the distance (clearance) between the orginal point and the ground. The tensile strength in the wire is 2500 N/em2. The weight of one meter of the conductor is 9 N. The cross-section area of the conductor is 4 cm2. (15 dearees)
Expert Solution
steps

Step by step

Solved in 5 steps with 2 images

Blurred answer
Knowledge Booster
Capacitor
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning