Examine the impact of the following circumstance on the PURITY of the sample. Decide whether the situation will INCREASE, DECREASE, HAVE NO EFFECT, or BE INDETERMINATE. EXPLAIN THE TREND IN THREE SENTENCES OR LESS IN THE "OTHER" Given Item IN THE OPTIONS. 1. The factor used in the computation of %P for calcium carbonate in complexamein, is 2. 2. In complexometric titration of calcium in the presence of magnesium, no masking agent was applied in the solution. 3. In the preparation and standardization of disodium edetate, mineral water was used. 4. The standardization of disodium edetate was conducted in acidic media. 5. Alcohol was not added in the standardization of Zinc Sulfate. 6. Titration of halides using argentometry is conducted in the presence of sunlight. 7. In the standardization of ammonium thiocyanate, 15 mL of 0.1 N silver nitrate VS was measured into a glass-stoppered flask, then titrated with ammonium thiocyanate.

Fundamentals Of Analytical Chemistry
9th Edition
ISBN:9781285640686
Author:Skoog
Publisher:Skoog
Chapter21: Potentiometry
Section: Chapter Questions
Problem 21.25QAP
icon
Related questions
Question

Answer 1-7 only

Examine the impact of the following circumstance on the PURITY of the sample. Decide whether the
situation will INCREASE, DECREASE, HAVE NO EFFECT, or BE INDETERMINATE. EXPLAIN
THE TREND IN THREE SENTENCES OR LESS IN THE "OTHER" Given Item IN THE OPTIONS.
1. The factor used in the computation of %P for calcium carbonate in complexometo, is 2.
2. In complexometric titration of calcium in the presence of magnesium, no masking agent was
applied in the solution.
3. In the preparation and standardization of disodium edetate, mineral water was used.
4. The standardization of disodium edetate was conducted in acidic media.
5. Alcohol was not added in the standardization of Zinc Sulfate. 6. Titration of halides using
argentometry is conducted in the presence of sunlight.
7. In the standardization of ammonium thiocyanate, 15 ml of 0.1 N silver nitrate VS was measured
into a glass-stoppered flask, then titrated with ammonium thiocyanate.
8. lodine flask was not used in iodometric titrations.
9. Mohr method was conducted in slightly acidic condition.
10. Acid-base indicator was used in replacement for the adsorption indicator in the titration of Eaians
method.
Transcribed Image Text:Examine the impact of the following circumstance on the PURITY of the sample. Decide whether the situation will INCREASE, DECREASE, HAVE NO EFFECT, or BE INDETERMINATE. EXPLAIN THE TREND IN THREE SENTENCES OR LESS IN THE "OTHER" Given Item IN THE OPTIONS. 1. The factor used in the computation of %P for calcium carbonate in complexometo, is 2. 2. In complexometric titration of calcium in the presence of magnesium, no masking agent was applied in the solution. 3. In the preparation and standardization of disodium edetate, mineral water was used. 4. The standardization of disodium edetate was conducted in acidic media. 5. Alcohol was not added in the standardization of Zinc Sulfate. 6. Titration of halides using argentometry is conducted in the presence of sunlight. 7. In the standardization of ammonium thiocyanate, 15 ml of 0.1 N silver nitrate VS was measured into a glass-stoppered flask, then titrated with ammonium thiocyanate. 8. lodine flask was not used in iodometric titrations. 9. Mohr method was conducted in slightly acidic condition. 10. Acid-base indicator was used in replacement for the adsorption indicator in the titration of Eaians method.
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Tools in Analytical Chemistry
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Fundamentals Of Analytical Chemistry
Fundamentals Of Analytical Chemistry
Chemistry
ISBN:
9781285640686
Author:
Skoog
Publisher:
Cengage
Appl Of Ms Excel In Analytical Chemistry
Appl Of Ms Excel In Analytical Chemistry
Chemistry
ISBN:
9781285686691
Author:
Crouch
Publisher:
Cengage
Chemical Principles in the Laboratory
Chemical Principles in the Laboratory
Chemistry
ISBN:
9781305264434
Author:
Emil Slowinski, Wayne C. Wolsey, Robert Rossi
Publisher:
Brooks Cole
Principles of Modern Chemistry
Principles of Modern Chemistry
Chemistry
ISBN:
9781305079113
Author:
David W. Oxtoby, H. Pat Gillis, Laurie J. Butler
Publisher:
Cengage Learning
Chemistry: Principles and Practice
Chemistry: Principles and Practice
Chemistry
ISBN:
9780534420123
Author:
Daniel L. Reger, Scott R. Goode, David W. Ball, Edward Mercer
Publisher:
Cengage Learning