Would the following procedural errors result in an incorrectly high or low calculated percent NaOCl in the commercial bleaching solution? Briefly explain. a) A student failed to allow the volumetric pipet to drain completely when transferring commercial bleaching solution to the volumetric flask. b) A student blew the last drops of bleaching solution from the pipet into the Erlenmeyer flask when transferring diluted bleaching solution to the flask. c) A student began a titration with an air bubble in the buret tip. The bubble remained in the buret tip during the first titration, but it came out of the tip with the titrant released during the second titration. d) A student added diluted bleaching solution and HCI solution to aqueous KI solution in Erlenmeyer flasks 1 and 2 before beginning the titration in Erlenmeyer flask 1.

Fundamentals Of Analytical Chemistry
9th Edition
ISBN:9781285640686
Author:Skoog
Publisher:Skoog
Chapter8: Sampling, Standardization, And Calibration
Section: Chapter Questions
Problem 8.14QAP
icon
Related questions
Question
Would the following procedural errors result
in an incorrectly high or low calculated
percent NaOCI in the commercial bleaching
solution? Briefly explain.
a) A student failed to allow the volumetric
pipet to drain completely when transferring
commercial bleaching solution to the
volumetric flask.
b) A student blew the last drops of bleaching
solution from the pipet into the Erlenmeyer
flask when transferring diluted bleaching
solution to the flask.
c) A student began a titration with an air
bubble in the buret tip. The bubble remained
in the buret tip during the first titration, but
it came out of the tip with the titrant
released during the second titration.
d) A student added diluted bleaching
solution and HCI solution to aqueous KI
solution in Erlenmeyer flasks 1 and 2 before
beginning the titration in Erlenmeyer flask 1.
Transcribed Image Text:Would the following procedural errors result in an incorrectly high or low calculated percent NaOCI in the commercial bleaching solution? Briefly explain. a) A student failed to allow the volumetric pipet to drain completely when transferring commercial bleaching solution to the volumetric flask. b) A student blew the last drops of bleaching solution from the pipet into the Erlenmeyer flask when transferring diluted bleaching solution to the flask. c) A student began a titration with an air bubble in the buret tip. The bubble remained in the buret tip during the first titration, but it came out of the tip with the titrant released during the second titration. d) A student added diluted bleaching solution and HCI solution to aqueous KI solution in Erlenmeyer flasks 1 and 2 before beginning the titration in Erlenmeyer flask 1.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Analytical Separations
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Fundamentals Of Analytical Chemistry
Fundamentals Of Analytical Chemistry
Chemistry
ISBN:
9781285640686
Author:
Skoog
Publisher:
Cengage
Appl Of Ms Excel In Analytical Chemistry
Appl Of Ms Excel In Analytical Chemistry
Chemistry
ISBN:
9781285686691
Author:
Crouch
Publisher:
Cengage
EBK A SMALL SCALE APPROACH TO ORGANIC L
EBK A SMALL SCALE APPROACH TO ORGANIC L
Chemistry
ISBN:
9781305446021
Author:
Lampman
Publisher:
CENGAGE LEARNING - CONSIGNMENT
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning