Very pure silver nitrate standard reagent requires standardization with primary standard NaCl or KCl True False A water sample was analyzed for the total hardness through the reaction between the sample and EDTA. The data obtained from the experiment are presented below (MM CaCO3 = 100.0869 g/mol): Table 1. Standrdization of the EDTA solution mass of CaCO3 used 0.5467 g Initial burette reading 8.25 mL Final burette reading 16.65 mL Volume consumed 8.40 mL Table 2. Determination of Hardness of Water Volume of water sample 25.00 mL Initial burette reading 15.00 mL Final burette reading 24.00 mL Volume consumed 9.00 mL
Very pure silver nitrate standard reagent requires standardization with primary standard NaCl or KCl True False A water sample was analyzed for the total hardness through the reaction between the sample and EDTA. The data obtained from the experiment are presented below (MM CaCO3 = 100.0869 g/mol): Table 1. Standrdization of the EDTA solution mass of CaCO3 used 0.5467 g Initial burette reading 8.25 mL Final burette reading 16.65 mL Volume consumed 8.40 mL Table 2. Determination of Hardness of Water Volume of water sample 25.00 mL Initial burette reading 15.00 mL Final burette reading 24.00 mL Volume consumed 9.00 mL
Chapter17: Complexation And Precipitation Reactions And Titrations
Section: Chapter Questions
Problem 17.42QAP
Related questions
Question
Very pure silver nitrate standard reagent requires standardization with primary standard NaCl or KCl
True
False
A water sample was analyzed for the total hardness through the reaction between the sample and EDTA. The data obtained from the experiment are presented below (MM CaCO3 = 100.0869 g/mol):
Table 1. Standrdization of the EDTA solution
mass of CaCO3 used | 0.5467 g |
Initial burette reading | 8.25 mL |
Final burette reading | 16.65 mL |
Volume consumed | 8.40 mL |
Table 2. Determination of Hardness of Water
Volume of water sample | 25.00 mL |
Initial burette reading | 15.00 mL |
Final burette reading | 24.00 mL |
Volume consumed | 9.00 mL |
23,469 ppm |
||
22,456 ppm |
||
21,290 ppm |
||
23,990 ppm |
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 2 steps
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Recommended textbooks for you
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Chemistry & Chemical Reactivity
Chemistry
ISBN:
9781337399074
Author:
John C. Kotz, Paul M. Treichel, John Townsend, David Treichel
Publisher:
Cengage Learning