Determine the overall column length that, if exceeded, would cause the column to buckle elastically before yielding. A W8x31 columns with fixed supports. Use steel with Fy=40 ksi. (W8x31 has Ag-9.12in², Iy-37.1in¹, Ix-110in, d-8in, bf-8in, tf-0.435in, h-22.3in, rx-3.47in, ry-2in). Check the limiting Width-thickness Ratio for the flange and web.
Q: A square rapid-mixing basin, with a depth of water equal to 1.25 times the width, is to be designed…
A:
Q: Two people weighing W each are sitting on a plank of
A:
Q: W 10k b Á
A:
Q: INUTO: Tom C] Draw the shear force V and bending moment M diagrams for the frame showr - Te
A: Given:- To find:- Shear force and bending moment diagram Concept:- Shear force diagram displays the…
Q: 1-49. The railcar lamp is supported by the -in.-diameter pin at A. If the lamp weighs 4 lb, and the…
A:
Q: Situation 4: Given the truss shown, determine the maximum value of the downward force P if the…
A:
Q: The concrete floor of a hand regulator is level with the channel bed and is 13 m long. The depth of…
A: Given Data Length of floor (b) = 13m Depth of U/s pile = 2.5 m Depth of D/s pile = 2m F.S.L =…
Q: Design an inverted syphon required to pass canal discharge of 4.2 m³/sec under a canal with 0.3 m…
A: An inverted Syphon is used to carry storm wastewater discharge or sewage in the ground.In this…
Q: INUTO: Top C] Draw the shear force V and bending moment M diagrams for the frame showr 135 KN - 4 m…
A:
Q: Determine the difference between the capitalized cost of the timber and steel penstock for a…
A: Capitalized cost is defined as the present worth of a constant annual cost over an infinite analysis…
Q: The reactions at the support for a simple beam loaded as shown. Neglect the weight of the beam. The…
A: Given: A simple beam with loadings Required: Support reactions Internal forces at C
Q: Question- A 5m high vertical earth retaining wall retains a dry granular backfill with angle of…
A:
Q: A pre tensioned concrete beam 100 mm wide and 300 mm deep, initial force of 150 kN at an…
A: Given 100 mm wide 300 mm deep Initial force P =150 kN at eccentricity e = 50 mm Moment of inertia…
Q: Q2) Fill the blank with suitable word or words: 1) The various types of heat-treating processes are…
A:
Q: A 5m high vertical earth retaining wall retains a dry granular backfill with angle of internal…
A:
Q: The most suitable distribution for transmissivity is?
A: The most suitable distribution for transmissivity is the Log-normally distributed transmissivity.…
Q: For the beams given below, sketch the moment and shear diagrams
A: Given data in question Load 10,10,20,10 & 10k Span 29 ft To find out SFD BMD
Q: Torsion A square beam of size 400 mm x 400 mm is subjected to a factored bending moment and twisting…
A: The size of the square beam = 400 mm × 400 mm The magnitude of the factored bending moment = 200…
Q: A post tension beam section drawn below consists of three cables of 100 mm² area. Initial…
A:
Q: + wide plange w/ the pollowing properties A shown below is to be used as a column with an effective…
A:
Q: Engineering Mechanics (Upvote will be given. Please write the complete solutions and FBDs Legibly.…
A: Given Data EI = constant Determined the support reaction.
Q: The following observations were made to determine the sensitivity of two bubble tubes. Determine…
A:
Q: 3. What mathematical law was being applied on the "General Rectilinear Motion" principle? Please…
A: The "General Rectilinear Motion" principle The "General Rectilinear Motion" principle refers to the…
Q: Determine the equilibrium speed and cant to be provided on a BG curve of 3 degree if the speeds of…
A: Given data, Degree of curve = 3° BG = 1.676 m Speed of different number of train, 15 train speed…
Q: Calculate the forces in members BC, BE, and EF. Solve for each force from an equilibrium equation…
A:
Q: At a coastal unconfined aquifer the density of the adjacent sea water is 1.041g / c * m ^ 3 What is…
A: Given: The density of sea water is 1.041 g/cm^3, and the water table is 1.3 m above sea level.
Q: What is the factor of safety and where is the most critical failure surface? - Assume planar…
A: Solution: Planar surface analysis: The factor of safety: F=ccm Where: c = stability cm = mobilized…
Q: A solid circular shaft of diameter d and length L is fixed at one end and free at the other end. A…
A: Given a solid circular shaft with, Diameter d. Length L is fixed at one end and free at another end.…
Q: A зоки/т Чт ще
A:
Q: Question- A 5m high vertical earth retaining wall retains a dry granular backfill with angle of…
A:
Q: Replace the 25-KN force acting on the steel column by an equivalent force-couple system at point O.…
A:
Q: A rectangular column section of 500 mm x 300 mm is reinforced with five steel bars of grade Fe-500…
A:
Q: The forward azimuth of line BC is 215.5 degrees, determine its back azimuth in degrees.
A:
Q: For system. If the pressure at Point A is go! Determine the pressures at Points B. Cand Din 个 дост…
A:
Q: B) Prove that = (1-n) (1 + wc) GsYw
A:
Q: How to input elevation, offset, side and station on microstation
A: In order to input elevation, offset, side and station on MicroStation, you will need to use the…
Q: explain the causes and process of a) Subsidence
A: Brief concept introduction- Subsidence Definition & Process- Subsidence is the movement of…
Q: Problem 1: From the vertical curve data given in the sketch below, calculate the values of G1 & G2.…
A: Given data PVI = 240.5 m PVC = 236.98 m PVT = 236.62 m L = 360 m
Q: Check the determinacy of the structures in Fig Hinge ingef
A: Given To check the determinacy
Q: A uniformly distributed Line Load of 500 kN/m is acting on the ground surface based on Boussinesq's…
A:
Q: 1-87. The beam is made from southern pine and is supported by base plates resting on brick work. If…
A:
Q: Question 1: True/False questions True or False 1 The lower the water turbidity, the higher the 6…
A: This question is related to Environment Engineering from Civil Engineering. This question is…
Q: A beam with a W360x45 section (Beam weight 45 kg) is used as a cantilever beam 7.5 m long. Find the…
A:
Q: Determine the cracking moment in kN-m for the section shown if: f'c = 28MPa fr=0.7(square root of…
A:
Q: Calculate spacing between expansion joints, if the expansion joint gap is 2.0 cm in a cement…
A: Given- Joint gap l= 2 cm=0.02 m Laying temperature =10oC Maximum slab temperature = 50oC It is…
Q: A 15 cm diameter pipe has a diffuser at its end. If the velocity of the fluid in the pipe is 10.11…
A: Given- Diameter of pipe D=15 cm Velocity V1=10.11 m/s Pressure P1=75 KPa, Coefficient of velocity…
Q: Determine variables requested below for a horizontal curve with the following characteristics.…
A: The given data is shown below: Curve length=1255'Radius=1200'PC ta=12+00Lane width=14…
Q: a. Compute reaction forces based on "W1". W1=10 kN. b. Compute internal forces/moments at a-a. W1 1m…
A:
Q: A P = 230 KN C B TIT D P
A:
Q: The concrete floor of a hand regulator is level with the channel bed and is 13 m long. The depth of…
A: Given:- The concrete floor of a hand regulator is level with the channel bed (b)is 13 m long The…
Trending now
This is a popular solution!
Step by step
Solved in 2 steps
- Q2) The members of the truss structure shown below is plain concrete. The compressive strength of the concrete is 25 MPa. Compute the maximum load P that can be carried by the structure. (Cross section of each member of the truss is 200 x 200 mm and don't use material factors and do not consider slenderness) Comment on your results briefly. P A& 2m SC 2 m 1380 2m Dsteel Design Civil Engineering Please show solutions: AW 310 x 118 section with a length of 8.0 m is used as a column. Determine the safe axial load the column can carry using AISC specifications with Fy = 345 MPa when: Properties of W 310 x 118 A = 15000 mm² rx = 136 mm ry = 77.6 mm A. column ends are fixed B. one end of the column is fixed; the other free Use LRFD Answers: A.] For Ag = 248.06X15000 100 3720,9kw $en=0.90x3720.9 = 3348.21 kW B.JPn= For Ag =40.72 x 15 000 LOW Pr= 0.90x610,81 = 549.729 KNdetermine the member stresses of the truss shown. indicate if the stress in the member is in tension or compression. present complete and neat solutions. p1-30kN W-25kN/m P2=51kN AH Av Im P₂ Im P₂ Im P₂ Im Av W 1.6m
- A column is constructed using a circular steel tube filled with concrete. The properties are listed below. Please find: 1. The maximum allowable axial force, P 2. Shortening (in inches) of a 12 ft column with this cross-section when P is applied 3. The strain in the steel when P is applied Table 1- Column Details OD E fs, allow 18 in. 29000 ksi 27 ksi ID Ec fc, allow 17.5 in. 3600 ksi 3 ksi1. A steel column 10 m long is fabricated from a cover plate and C section arranged as shown. Determine the safe compressive load. Fy = 248 MPa, E= 200 GPa. Use AISC/NSCP Specs. 450 mm -cover plate 'I 12 mm y2 IP d2 10 m C 310 x 37 A = 4720 mm? d = 305 mm bf = 77 mm tf = 12.7 mm tw = 9.8 mm C 310 X 37 a) Both ends of column are fixed b) Both ends of column are hinged c) One end fixed, the other end hinged Use design values of k. tw d=305- Ix = 59.9x10° mm ly = 1.85x10° mm x = 17.1 mm x=17.1Questions: Civil Engineering - Steel Find the maximum axial load that the W200 x 46 column can safely carry if its effective length is 6m. Fy = 248 MPa and E = 200 GPa. Use ASD. Section Properties A = 5860 mm2 I= 15.3 x 106 mm4 r = 51.1 mm Final Answerri Pn - 703.87 こ 22 1-67 = Design 421.481N Pn= For Ag 120.11X580O (n = 703.87kW :. Please show solutions on how to get the answers 421.48 kW
- Determine whether the D = 560 kips L = 68 kips compression member shown is adequate to support the given service loads. Take %3D note Pu = 1.4D. 20' W12 x 79 = 3.05 in K = 0.80, r= E = 29000 ksi, Fy = 50 ksi A992 steel Input Yes or No for your final answer. Note: Ag = 23.2 in^2USE NSCP 2010 A rectangular beam reinforced for both tension and compression barshas an area of 1450 mm² for compression bars and 4350 mm² fortension bars. The tension bars and compression bars are placed at a distance of 600 mm and 62.5 mm respectively from the top of thebeam. The beam width 300 mm, fc’ = 21 MPa, fy = 415 MPa andtension steel covering is 60 mm.If it is 8 m-simply-supported beam that carries three concentratedservice live loads P applied at three quarter points of the beam (exceptat the supports), neglecting the self weight of the beam, determine themaximum value of service load P in kiloNewtons.Q2. Design the required tensile and compression rebars for the cross section shown below. Mu= 288 kN.m fc=20 MPa , fy= 300 MPa 60 340 100 250 |
- AW14 x 53 of Grade 70 steel is used as a compression member. It is 30 feet long, pinned at the top and fixed at the bottom, and has additional bracing in the weak direction. The column is braced (pinned) on its weak axis 10 ft form the top and bottom. What is the nominal strength in axial compression for the member? O 659 kips O 761 kips O 856 kips O 733 kipsDetermine whether the D = 560 kips L = 68 kips compression member shown is adequate to support the given service loads. Take note Pu = 1.4D. 20' W12 × 79 K = 0.80, r = 3.05 in E = 29000 ksi, Fy = 50 ksi %3D A992 steel Input Yes or No for your final answer. Blank 1 Blank 1 Add your answer• AW 310 x 118 section with a length of 8.0 m is used as a column. Determine the safe axial load the column can carry using AISC specifications with Fy = 345 MPa when: a) column ends are fixed b) one end of the column is fixed; the other free Properties of W 310 x 118 A = 15000 mm² rx = 136 mm ry = 77.6 mm CIVIL ENGINEERING- STEEL DESIGN